VIVIX-S 1751S
Single-shot exposure for 17" x 51" image
- Long & wide active area for one-shot long bone
and full spine scan (43 x 129 cm) - Low dose exposure for patients
- Streamlined workflow with short image acquisition time (8 sec.)
Multi-scan mode
Multi-scan mode for selective body part imaging
Superior Image Quality
140 ㎛ pixel pitch for sharp, high-resolution diagnostic images
Specifications
Model Name
FXRD-1751SA | FXRD-1751SB
Technology
a-Si TFT
Scintillator
CsI | Gadox
Pixel Pitch
140 ㎛
Spatial Resolution
3.5 lp/㎜
Pixel Matrix
3072 x 9216 pixels
3072 × 6144 pixels
3072 × 3072 pixels
Image Size
17″ × 51″ (43.0 cm × 129.0 cm)
17″ × 34″ (43.0 cm × 86.0 cm)
17″ × 17″ (43.0 cm × 43.0 cm)
Grayscale
16 bits
Image Acquisition Time
8 sec.
Recommended Cycle Time
15 sec.
Data Interface
Gigabit Ethernet
X-ray Generator Interface
DR trigger Mode | AED Mode
Dimensions
135.7 cm × 53.2 cm × 3.0 cm
Weight
19.7 kg
X-ray Voltage Range
40 – 150 kVp
Operating Environment
10℃ to 35℃
30 % to 85 % RH (non-condensing)
Power Consumption
DC 24 V, 3.0 A
M70 integrates uSeed’s high-end imaging technology and image algorithm, offering excellent images, comprehensive functions, efficient workflow, and convenient mobility ina single machine for dual-use (desktop and portable). It can be easily operated in ultrasound departments or for mobile diagnosis and treatment applications, showcasing outstanding performance in obstetrics and gynecology applications.
Ergonomic Design
Efficient and Fast Workflow
- Multiple user-defined programming buttons
- One-key Automatic Optimization Technology
- One-key operation flow, quick switching and easy to use
- Visualize user-defined presets function (QSave)
- Metadata and image postprocessing
- DICOM 3.0
- USB 3.0 port, make transmission more convenient
- Thumbnail clipboard - easy to review the images and videos
- Ultrasound Assistance
Clipboard
User-defind Buttons
Station
QSave
Comprehensive Clinical Applications
M70 provides remarkable performance in Abdomen, Gynecology (including endocavity), Obstetric, Cardiology, Small parts (Breast, Testes, Thyroid, etc.), Urology, Musculoskeletal andPeripheral vascular.Avariety of imaging modes brings a comprehensive clinical application.
- B Steer,TSl,THl, SRl,SCl,FCl,Biopsy Function
- Auto IMT, Auto Trace,Panoramic lmaging,Elastic Imaging,EFOV
- Auto EF, PW,CW,TDI,AMM, Curved AMM,CMM
- Auto OB ,Auto NT,3D/4D,ZPage,ZLive,Auto Follicle
Extraordinary Clinical Images
Reaction system
The grated photometer is designed for maintenance-free operation, featuring 12 wavelengths to ensure precise and reliable measurements. With a broad photometric linearity of up to 3.5 OD, it minimizes the need for repetitions and thus increases efficiency and accuracy. The system also includes maintenance-free thermostatization of cuvettes through air heating, which eliminates the need for time-consuming servicing of a water bath. Additionally, the twin test functionality supports the DiaSys HbA1c net FS assay, optimizing performance for specific diagnostic applications.
Advanced HbA1c testing
The system features fully automated onboard hemolyzation of whole blood samples, avoiding time-consuming and error-prone manual sample preparation. HbA1c smart sampling ensures efficient aspiration of erythrocytes even in samples with higher sedimentation rate by sampling at the bottom of the tube. After processing a whole blood sample, a deep washing of the sample probe minimizes carryover, enhancing accuracy and reliability.
Reagent/Sample rotor
respons®240c offers an onboard capacity of up to 36 DiaSys respons® bottles in an refrigerated reagent rotor (2-12°C). In combination with the dedicated respons® bottles, a convenient one grip loading also for two component reagents is ensured. Additionally, 36 flexible positions are available for samples/calibrators/controls.
Reagent/Sample probe
The liquid level detection system of the analyzer prevents dry aspiration and ensures in combination with the sample clot detection functions an accurate sample handling. Collision detection protects the probe from damage, while real time inventory monitoring provides a clear overview of remaining tests. Additionally, sample clot detection enhances result reliability.
- Throughput – 240 tests/hour (400 tests/hour incl. optional ISE)
- Sample types – Serum, plasma, urine, whole blood
- Sample volume – 2-35 μL, 0.1 μL steps
- Reagent/Sample probe – Liquid level detection, clot detection and collision protection
- Reagent pipetting – 10-200 μL, 0.5 μL steps
- STAT-analytics – Yes
Ion measurement – ISE upgrade kit available
- Barcode identification – Sample, reagent
- Sample tray – 36 samples
- Reagent on board capacity – 34 respons® containers cooled to 2-12°C
- Reaction unit – 80 cuvettes, 8-step auto-washing
- Photometry – Grating system, 12 wavelengths (340, 380, 412, 450, 505, 546, 570, 605, 660, 700, 740 and 800 nm)
- Photometric linearity and resolution – 0-3.5 OD, 0.0001 OD
- Water consumption – < 6.5 liters per hour
- Dimensions – 86 cm (W) × 66 cm (D) × 55 cm (H)
- Weight – approx. 115 kg
Product Feature
Compatibility
Two modes of sampling: Whole blood, pre-diluted blood. Build-in thermal printer, external laser printer or inkjet printer.
User-friendly
10.4 colorful touchscreen. Liquid Crystal Display. Resolution : 800600. 10°incline adapt to visual observation
Less Maintenance
Auto-cleaning of sample probe and tubes. Automatic fault processing function
Low Consumption
Only need three reagents. Sample consumed ≤20uL
Efficient
60 samples per hour
Lightweight
390mm(L)×285mm(W)×390mm(H) Weight≤16Kg
Product Video
Specifications
- WBC
- RBC
- HGB
- MCV
- PLT
● Precision – ≤2.0% (3.5-15.0×10^9)/L
● Linear Range – (0-100.0×10^9)/L
● Contamination Rate – ≤0.5%
● Precision – ≤1.5% (3.0-6.0×10^12)/L
● Linear Range – (0.10-8.00×10^12)/L
● Contamination Rate – ≤0.5%
● Precision – ≤1.5% (100-180) g/L
● Linear Range – (0-250) g/L
● Contamination Rate – ≤0.6%
● Precision – ≤1.0% (70-120)fL
● Linear Range – ( – )
● Contamination Rate – ( – )
● Precision – ≤4.0% (150-500×10^9)/L
● Linear Range – (0-1000×10^9)/L
● Contamination Rate – ≤1.0%