Cart-based Color
Ultrasound

Precision in compactness

Compact & Fully-Automated Bench Top Analyzer

Experience efficient and reliable laboratory testing with respons®240c. This fully automated bench top analyzer is perfect for small laboratories since it offers a constant throughput of 240 tests per hour (400 tests/hour incl. optional ISE). Its compact design and user friendly interface provide a valuable asset to any laboratory. Benefit from low operating costs, minimal maintenance and precise results.

ViV 80 is based on Zoncare’s brand-new uSeed metadata ultra-fast imaging technology platform, adopts CPU+GPU dual-processor heterogeneous computing technology, which breaks through the technical challenge of high loss in front-end signal processing of traditional ultrasound platforms, and has higher hardware circuit integration and better performance,stronger and faster response; At the same time, ViV 80 is equipped with a new generation of pure wave single-crystal probe and a broadband high-frequency probe dedicated to breast&thyroid, which can truly reflect the original appearance of tissues and represent anatomical details.

Single Crystal Multi-matching Layer Probe

Applied to the Abdomen& Cardiology, provide wider bandwidth, stronger penetration and higher resolution, effectively overcome the artifacts produced by the endocardium and subtle tissue structures, and gain insight into the edge between blood flow and tissue. Provide better probe solutions for the difficult patients.

Various probe configuration

5 active probe ports

Various probe configuration

5 active probe ports

Fundamental and Harmonic Fusion Imaging

Combining the advantages of high detail resolution of tissue harmonic imaging and deep penetration of fundamental wave imaging, the overall image quality is improved.

Real-time Elastography

The Real-time Elastography technology based on acoustic energy and shear wave velocity can provide fast, accurate and better penetrating real-time quantitative elastic images, and provide clinical quantitative evaluation of tissue soft and hard lesions.

Nonlinear Parametric Imaging

Quantitative imaging of non-linear parameters inside the tissue can be performed, and it has good clinical application value in the identification of liver diseases.

3D Spectral Imaging

Through the multi-sampling gate three-dimensional Doppler spectrum technology, it can display the velocity waveform and three-dimensional spectrum of the blood vessel section, and provide accurate flow calculation.

Excellent Clinical Images

Reaction system

The grated photometer is designed for maintenance-free operation, featuring 12 wavelengths to ensure precise and reliable measurements. With a broad photometric linearity of up to 3.5 OD, it minimizes the need for repetitions and thus increases efficiency and accuracy. The system also includes maintenance-free thermostatization of cuvettes through air heating, which eliminates the need for time-consuming servicing of a water bath. Additionally, the twin test functionality supports the DiaSys HbA1c net FS assay, optimizing performance for specific diagnostic applications.

Advanced HbA1c testing

The system features fully automated onboard hemolyzation of whole blood samples, avoiding time-consuming and error-prone manual sample preparation. HbA1c smart sampling ensures efficient aspiration of erythrocytes even in samples with higher sedimentation rate by sampling at the bottom of the tube. After processing a whole blood sample, a deep washing of the sample probe minimizes carryover, enhancing accuracy and reliability.

Reagent/Sample rotor

respons®240c offers an onboard capacity of up to 36 DiaSys respons® bottles in an refrigerated reagent rotor (2-12°C). In combination with the dedicated respons® bottles, a convenient one grip loading also for two component reagents is ensured. Additionally, 36 flexible positions are available for samples/calibrators/controls. 

Reagent/Sample probe

The liquid level detection system of the analyzer prevents dry aspiration and ensures in combination with the sample clot detection functions an accurate sample handling. Collision detection protects the probe from damage, while real time inventory monitoring provides a clear overview of remaining tests. Additionally, sample clot detection enhances result reliability.

  • Throughput – 240 tests/hour (400 tests/hour incl. optional ISE)
  • Sample types – Serum, plasma, urine, whole blood
  • Sample volume – 2-35 μL, 0.1 μL steps
  • Reagent/Sample probe – Liquid level detection, clot detection and collision protection
  • Reagent pipetting – 10-200 μL, 0.5 μL steps
  • STAT-analytics – Yes
  • Ion measurement – ISE upgrade kit available

  • Barcode identification – Sample, reagent
  • Sample tray – 36 samples
  • Reagent on board capacity – 34 respons® containers cooled to 2-12°C
  • Reaction unit – 80 cuvettes, 8-step auto-washing
  • Photometry – Grating system, 12 wavelengths (340, 380, 412, 450, 505, 546, 570, 605, 660, 700, 740 and 800 nm)
  • Photometric linearity and resolution – 0-3.5 OD, 0.0001 OD
  • Water consumption – < 6.5 liters per hour
  • Dimensions – 86 cm (W) × 66 cm (D) × 55 cm (H)
  • Weight – approx. 115 kg

Product Feature

Compatibility

Two modes of sampling: Whole blood, pre-diluted blood. Build-in thermal printer, external laser printer or inkjet printer. 

User-friendly

10.4 colorful touchscreen. Liquid Crystal Display. Resolution : 800600. 10°incline adapt to visual observation

Less Maintenance

Auto-cleaning of sample probe and tubes. Automatic fault processing function

Low Consumption

Only need three reagents. Sample consumed ≤20uL

Efficient

60 samples per hour

 

Lightweight

390mm(L)×285mm(W)×390mm(H) Weight≤16Kg

Product Video

Specifications

● Precision – ≤2.0% (3.5-15.0×10^9)/L

● Linear Range – (0-100.0×10^9)/L

● Contamination Rate – ≤0.5%

● Precision – ≤1.5% (3.0-6.0×10^12)/L

● Linear Range – (0.10-8.00×10^12)/L

● Contamination Rate – ≤0.5%

● Precision – ≤1.5% (100-180) g/L

● Linear Range – (0-250) g/L

● Contamination Rate – ≤0.6%

● Precision – ≤1.0% (70-120)fL

● Linear Range – ( – )

● Contamination Rate – ( – )

● Precision – ≤4.0% (150-500×10^9)/L

● Linear Range – (0-1000×10^9)/L

● Contamination Rate – ≤1.0%

Reliability in routine

Compact & Fully-Automated Bench Top Analyzer

Experience laboratory work redefined. respons®420c is a fully automated random access analyzer designed to deliver reliable results with a constant throughput of up to 420 tests per hour (620 tests/hour incl. ISE). Due to its optimal cost-effectiveness and ease of use, it perfectly fits in small to medium sized laboratories.

Based on the increasing demand for clinical examination and the multidisciplinary integration in the field of ultrasound, intelligence and precision have become the main medical trends at present, ViV 70 has insight into user needs, is committed to assisting clinicians to carry out efficient and accurate disease diagnosis, and brings users the ultimate comfortable control experience!

High Performance Probe Cluster

Single-crystal multi-matching layer probe, which can provide wider bandwidth, stronger penetration and higher resolution for convex array and phased array probes; The 4D probe made of composite crystal material and imported stepping micro-motor is lighter, less noisy and better image quality than traditional volumetric probe; The perfect probe configuration scheme can cover the clinical examination needs of different departments in different hospitals.

Smart and Efficient Clinical Applications

High-resolution Blood Flow Imaging

Significantly improve the blood flow imaging ability of very small blood vessels, helping to achieve accurate clinical diagnosis.

AI Obstetric Automatic Measurement

Automatically identify standard sections and automatically measure fetal double parietal diameter, head and tail, abdominal circumference, femur and other items to improve the efficiency of prenatal examination.

Automated Workflow Agreements

Customizing the workflow according to user needs can reduce the number of keystrokes by 80% and save 30% of inspection time.

Excellent Clinical Images

Reaction system

The grated photometer is designed for maintenance-free operation, featuring 12 wavelengths to ensure precise and reliable measurements. With a broad photometric linearity of up to 3.5 OD, it minimizes the need for repetitions and thus increases efficiency and accuracy. The system includes maintenance-free thermostatization of the cuvettes by contact heating (metal block), which ensures stable temperature control. Additionally, the twin test functionality supports the DiaSys HbA1c net FS assay, optimizing performance for specific diagnostic applications.

Reagent rotor

respons®420c offers an onboard capacity of up to 40 DiaSys respons® bottles in a refrigerated reagent rotor (2-8°C). In combination with the dedicated respons® bottles, a convenient one grip loading also for two component reagents is ensured. Additionally, 40 flexible positions are available for samples/calibrators/controls. 

Sample rotor

In total 102 positions, including 68 positions (outer ring) with automatic barcode reading and additional 34 positions (inner ring) designated for calibrators (10), controls (9), STAT samples (11), and cleaners (4) are available on the sample rotor. It hosts all major primary tubes and sample cups while ensuring high-priority processing of STAT samples. Additionally, auto dilution and automatic adaptation of the measuring window in case of substrate depletion minimize manual work, reduce rerun costs, and optimize turn around time.

Advanced HbA1c testing

The system features fully automated onboard hemolyzation of whole blood samples, avoiding time-consuming and error-prone manual sample preparation. HbA1c smart sampling ensures efficient aspiration of erythrocytes even in samples with higher sedimentation rate by sampling at the bottom of the tube. After processing a whole blood sample, a deep washing of the sample probe minimizes carryover, enhancing accuracy and reliability.

  • Throughput – 2420 tests/hour (with ISE 620 tests/hour)
  • Sample types – Serum, plasma, urine, whole blood
  • Sample volume – 2-45 μL, 0.1 μL steps
  • Sample probe – Liquid level detection, clot detection and collision protection
  • Reagent pipetting – 10-200 μL, 0.5 μL steps
  • Reagent probe – Liquid level detection, bubble detection and collision protection
  • STAT-analytics – Yes
  • Ion measurement – Optional ISE (Na, K, Cl)

  • Barcode identification – Sample, reagent
  • Sample tray – 102 positions
  • Reagent on board capacity – 40 respons® containers cooled to 2-8°C
  • Reaction unit – 93 cuvettes, 8-step auto-washing
  • Photometry – Grating system, 12 wavelengths (340, 380, 412, 450, 505, 546, 570, 605, 660, 700, 740 and 800 nm)
  • Photometric linearity and resolution – 0-3.5 OD
  • Water consumption – < 20 liters per hour
  • Dimensions – 105 cm (W) × 72 cm (D) x 115 cm (H)
  • Weight – approx. 200 kg

Product Feature

Compatibility

Two modes of sampling: Whole blood, pre-diluted blood. Build-in thermal printer, external laser printer or inkjet printer. 

User-friendly

10.4 colorful touchscreen. Liquid Crystal Display. Resolution : 800600. 10°incline adapt to visual observation

Less Maintenance

Auto-cleaning of sample probe and tubes. Automatic fault processing function

Low Consumption

Only need three reagents. Sample consumed ≤20uL

Efficient

60 samples per hour

 

Lightweight

390mm(L)×285mm(W)×390mm(H) Weight≤16Kg

Product Video

Specifications

● Precision – ≤2.0% (3.5-15.0×10^9)/L

● Linear Range – (0-100.0×10^9)/L

● Contamination Rate – ≤0.5%

● Precision – ≤1.5% (3.0-6.0×10^12)/L

● Linear Range – (0.10-8.00×10^12)/L

● Contamination Rate – ≤0.5%

● Precision – ≤1.5% (100-180) g/L

● Linear Range – (0-250) g/L

● Contamination Rate – ≤0.6%

● Precision – ≤1.0% (70-120)fL

● Linear Range – ( – )

● Contamination Rate – ( – )

● Precision – ≤4.0% (150-500×10^9)/L

● Linear Range – (0-1000×10^9)/L

● Contamination Rate – ≤1.0%

  • Power – Voltage: AC 100V~240V, 50/60Hz; Rated Power: 120VA
  • Principle – Electric impedance method and Colorimetry method
  • Parameters – WBC, LYM#, MID#, GRAN#, LYM%, MID%, GRAN%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC 3 histograms
  • Reagents – Build-in LH Lyse, External Diluent, Probe Cleaner for maintenance
  • Flag System – RBC, WBC, PLT abnormal sample and support customized test groups
  • Storage – Up to 50,000 results including histograms, scattergrams and patient information.
  • Quality Control – 3 Level QC, L-J graph, X-B

  • Calibration – Manual and Auto-calibration
  • Accessories – Standard: keyboard, waste liquid barrel, ground wire(3m); Option: mouse, external barcode scanner
  • Operational Environment – Working Temperature: 10℃~35℃; Relative Humidity: 20%~85%
Compact & Fully-Automated Bench Top Analyzer

Excellent Ergonomics

Won the “Red Dot Award” of the German Industrial Design Award
10.4-Inch high-definition touch screen with grid background brings diagnostic-level precision.
Built-in virtual keyboard for inputting information.
12-Lead synchronous acquisition, display, measurement and analysis.

ViV 60 inherits uSeed’s advanced technology platform, adopts CPU+GPU multi-core parallel processing technology. Equipped with high-performance single crystal probe and composite crystal probe, can provide ultrasound images with wider bandwidth, better penetration and resolution. Accurate and efficient, comprehensively enhance the confidence of clinical diagnosis.

zMicroflow

Significantly improve the sensitivity of color blood flow signals of micro-vessels in tissues such as the kidney, endocardium, and lymph nodes, which truly reflect changes in blood flow.

zonClear

Effectively reduce speckle noise, greatly enhance the edge of tissue boundaries and tissue echoes.

Auto IMT

It can automatically identify and measure the IMT of blood vessels, provide the IMT measurement report, and provide evaluation indicators for the prevention of cardiovascular and cerebrovascular events.

Panoramic Imaging

It can provide a more comprehensive scanning field of view and bring accurate and efficient clinical diagnosis.

TDI

Supports Tissue Doppler Imaging (TVI, TEI, TVM and TVD)

Innovative Ergonomic Design

The display and control panel adopt a floating design, which can be flexibly adjusted in all directions and from multiple angles

21.5 inch high resolution LED monitor

13.3 inch high-sensitivity touch screen with adjustable display angle, more intuitive, convenient and efficient operation

4 activated transducer connectors

The display and control panel adopt a floating design, which can be flexibly adjusted in all directions and from multiple angles

21.5 inch high resolution LED monitor

13.3 inch high-sensitivity touch screen with adjustable display angle, more intuitive, convenient and efficient operation

4 activated transducer connectors

Innovative Ergonomic Design

Support local storage of more than 2,000 reports and extended storage of USB or SD card.
Support internal thermal printer and external printer.

Networking and Connectivity

Standard wired and Wi-Fi networking functions
Multi-format exports are available, such as PNG, DCM, XML, HL7, PDF, JPG, GDT, ZQECG and etc.
Without any third-party software, iMAC 12 is able to directly access hospital systems via HL7/DICOM protocol.

Reaction system

The grating photometer has 16 wavelengths for maintenance-free operation and ensures precise and reliable measurements. With a wide photometric linearity of up to 3.5 OD, it minimizes the need for reruns and increases efficiency. The system includes maintenance-free thermostatization of the cuvettes by contact heating (metal block), which ensures stable temperature control. In addition, the twin test functionality supports the DiaSys HbA1c net FS assay, optimizing performance for specific diagnostic applications.

Advanced HbA1c testing

The system features fully automated onboard hemolyzation of whole blood samples, avoiding time-consuming and error-prone manual sample preparation. HbA1c smart sampling ensures efficient aspiration of erythrocytes even in samples with higher sedimentation rate by sampling at the bottom of the tube. After processing a whole blood sample, a deep washing of the sample probe minimizes carryover, enhancing accuracy and reliability.

Reagent rotor

respons®600c features a refrigerated reagent rotor (2-8°C) to ensure optimal storage conditions. It supports an onboard capacity of up to 37 DiaSys respons® reagent bottles. Convenient one grip loading of respons® bottles, including two-component reagents, eliminates the risk of misplacement. Due to the intelligent design of respons®600c, reagents can be load continuously during the run which enhances efficiency and shortens turn around time.

Automation

The analyzer is equipped with an integrated rack loader with continuous sample loading. With a total of 120 sample positions, including up to 30 STAT positions, it allows for high-throughput processing and extended walk-away time. Intelligent rerun and smart dilution functions optimize the workflow. The system offers a wake-up time of just 10 minutes, with a programmable start time. Additionally, HIL sample management ensures reliable result interpretation, and the integrated ISE provides exceptional onboard stability for up to nine months.

  • Throughput – 600 tests/hour (with ISE 800 tests/hour)
  • Sample types – Serum, plasma, urine, whole blood
  • Sample volume – 1.5-45 μL, 0.1 μL steps
  • Sample probe – Liquid level detection, clot detection and collision protection
  • Reagent pipetting – 10-200 μL, 0.5 μL steps
  • Reagent probe – Liquid level detection, bubble detection and collision protection
  • STAT-analytics – Yes, 3 racks
  • Ion measurement – Integrated ISE (Na, K, Cl)

  • Barcode identification – Sample, reagent
  • Sample tray – 120 samples by 12 racks
  • Reagent on board capacity – 37 respons® containers cooled to 2-8°C
  • Reaction unit – 124 cuvettes, 8-step auto-washing
  • Photometry – Grating system, 16 wavelengths (340, 380, 412, 450, 480, 505, 546, 570, 605, 630, 660, 700, 740, 770, 800 and 850)
  • Photometric linearity – 0-3.5 OD
  • Water consumption – < 25 liters per hour
  • Dimensions – 138 cm (W) x 86 cm (D) x 120 cm (H)
  • Weight – aapprox. 350 kg

Product Feature

Compatibility

Two modes of sampling: Whole blood, pre-diluted blood. Build-in thermal printer, external laser printer or inkjet printer. 

User-friendly

10.4 colorful touchscreen. Liquid Crystal Display. Resolution : 800600. 10°incline adapt to visual observation

Less Maintenance

Auto-cleaning of sample probe and tubes. Automatic fault processing function

Low Consumption

Only need three reagents. Sample consumed ≤20uL

Efficient

60 samples per hour

 

Lightweight

390mm(L)×285mm(W)×390mm(H) Weight≤16Kg

Product Video

Specifications

● Precision – ≤2.0% (3.5-15.0×10^9)/L

● Linear Range – (0-100.0×10^9)/L

● Contamination Rate – ≤0.5%

● Precision – ≤1.5% (3.0-6.0×10^12)/L

● Linear Range – (0.10-8.00×10^12)/L

● Contamination Rate – ≤0.5%

● Precision – ≤1.5% (100-180) g/L

● Linear Range – (0-250) g/L

● Contamination Rate – ≤0.6%

● Precision – ≤1.0% (70-120)fL

● Linear Range – ( – )

● Contamination Rate – ( – )

● Precision – ≤4.0% (150-500×10^9)/L

● Linear Range – (0-1000×10^9)/L

● Contamination Rate – ≤1.0%

  • Power – Voltage: AC 100V~240V, 50/60Hz; Rated Power: 120VA
  • Principle – Electric impedance method and Colorimetry method
  • Parameters – WBC, LYM#, MID#, GRAN#, LYM%, MID%, GRAN%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC 3 histograms
  • Reagents – Build-in LH Lyse, External Diluent, Probe Cleaner for maintenance
  • Flag System – RBC, WBC, PLT abnormal sample and support customized test groups
  • Storage – Up to 50,000 results including histograms, scattergrams and patient information.
  • Quality Control – 3 Level QC, L-J graph, X-B

  • Calibration – Manual and Auto-calibration
  • Accessories – Standard: keyboard, waste liquid barrel, ground wire(3m); Option: mouse, external barcode scanner
  • Operational Environment – Working Temperature: 10℃~35℃; Relative Humidity: 20%~85%

Part Auto Hematology Analyzer

Compact & Fully-Automated Bench Top Analyzer
  1. Efficient testing with precision reference laboratory quality results

  2. Compatibility with two modes of sampling and various printing options

  3. User-friendly with auto-cleaning of sample probe and tubes and automatic fault processing function

  4. Low consumption of only three reagents and ≤20uL of sample

  5. Lightweight design for easy portability

    – 2 Reagents
    – 21 Parameters
    – 60 Samples/hour
    – Low consumption of reagent and sample

ViV 40 inherits a number of imaging technologies and advanced application functions of uSeed’s high-end technology platform, with compact appearance, excellent performance, powerful functions, efficient workflow. ViV 40 also has outstanding performance in the field of cardiology while taking into account the whole-body application.

Comprehensive Clinical Applications

ViV 40 provides remarkable performance in Abdomen, Gynecology (including endocavity), Obstetric, Cardiology, Small parts (Breast, Testes, Thyroid, etc.), Urology, Musculoskeletal and Peripheral vascular. A variety of imaging modes brings a comprehensive clinical application.

Intelligent Blood Flow Tracking

Intelligently identify the location of blood vessels .Continuous tracking of blood flow, and support real-time optimization to achieve better blood flow optimization.

AMM

AMM allows up to three sampling lines to be placed at any Angle, facilitating multi-directional observation of ventricular wall movement.

Auto EF

To recognize myocardial intima during the diastolic and systolic period and calculate the ejection fraction automatically.Reduce the operation steps of inspectors and improve work efficiency.

User-friendly Ergonomics

Super large display

Versatile peripheral interface

Four activated universal probe port

Rotatable operation panel

Super large display

Versatile peripheral interface

Four activated universal probe port

Rotatable operation panel

User-friendly Ergonomics

Product Feature

Compatibility

Two modes of sampling: Whole blood, pre-diluted blood. Build-in thermal printer, external laser printer or inkjet printer. 

User-friendly

10.4 colorful touchscreen. Liquid Crystal Display. Resolution : 800600. 10°incline adapt to visual observation

Less Maintenance

Auto-cleaning of sample probe and tubes. Automatic fault processing function

Low Consumption

Only need three reagents. Sample consumed ≤20uL

Efficient

60 samples per hour

 

Lightweight

390mm(L)×285mm(W)×390mm(H) Weight≤16Kg

Product Video

Specifications

● Precision – ≤2.0% (3.5-15.0×10^9)/L

● Linear Range – (0-100.0×10^9)/L

● Contamination Rate – ≤0.5%

● Precision – ≤1.5% (3.0-6.0×10^12)/L

● Linear Range – (0.10-8.00×10^12)/L

● Contamination Rate – ≤0.5%

● Precision – ≤1.5% (100-180) g/L

● Linear Range – (0-250) g/L

● Contamination Rate – ≤0.6%

● Precision – ≤1.0% (70-120)fL

● Linear Range – ( – )

● Contamination Rate – ( – )

● Precision – ≤4.0% (150-500×10^9)/L

● Linear Range – (0-1000×10^9)/L

● Contamination Rate – ≤1.0%

  • Power – Voltage: AC 100V~240V, 50/60Hz; Rated Power: 120VA
  • Principle – Electric impedance method and Colorimetry method
  • Parameters – WBC, LYM#, MID#, GRAN#, LYM%, MID%, GRAN%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC 3 histograms
  • Reagents – Build-in LH Lyse, External Diluent, Probe Cleaner for maintenance
  • Flag System – RBC, WBC, PLT abnormal sample and support customized test groups
  • Storage – Up to 50,000 results including histograms, scattergrams and patient information.
  • Quality Control – 3 Level QC, L-J graph, X-B

  • Calibration – Manual and Auto-calibration
  • Accessories – Standard: keyboard, waste liquid barrel, ground wire(3m); Option: mouse, external barcode scanner
  • Operational Environment – Working Temperature: 10℃~35℃; Relative Humidity: 20%~85%
Compact & Fully-Automated Bench Top Analyzer

Compact and Portable

It weighs only 100g and can support standard twelve-lead synchronous acquisition.
Standard water-proof suitcase for easy portability.

As a brand new generation color doppler, ViV 20 is economical, practical, sturdy, durable, simple and easy to use; Especially integrated with extraordinary image quality and comprehensive function configurations, ViV 20 delivers more-than-expected clinical application experience.

Adaptive Spatial Filter Imaging- zonClear

ViV 20 is configurated with advanced adaptive spatial filter algorithm and combined with motion-compensated temporal filtering technique. It can effectively reduce speckle noise, significantly enhance tissue boundary display capability and tissue echo display capability through anatomical boundaries location detection.

Pulse Inversion Harmonic Imaging  PIHI

Under PIHI, two pulse waves of opposite phase position are transmitted simultaneously, echoes superposition processing is triggered and fundamental wave-forms signal is canceled, realizing 6db harmonic wave-forms. PIHI is able to reduce speckle noise effectively and significantly enhance image contrast and resolution.

Intima-media Thickness Auto Measurement. IMT.

Under IMT, intima-media thickness can be automatically detected and measured and intima-media thickness report can be generated, providing independent predictors for the prevention of cardiovascular events

User-friendly Ergonomics

Super large display

Versatile peripheral interface

Four activated universal probe port

Rotatable operation panel

Super large display

Versatile peripheral interface

Four activated universal probe port

Rotatable operation panel

Extraordinary Clinical Images

Product Feature

Compatibility

Two modes of sampling: Whole blood, pre-diluted blood. Build-in thermal printer, external laser printer or inkjet printer. 

User-friendly

10.4 colorful touchscreen. Liquid Crystal Display. Resolution : 800600. 10°incline adapt to visual observation

Less Maintenance

Auto-cleaning of sample probe and tubes. Automatic fault processing function

Low Consumption

Only need three reagents. Sample consumed ≤20uL

Efficient

60 samples per hour

 

Lightweight

390mm(L)×285mm(W)×390mm(H) Weight≤16Kg

Product Video

Specifications

● Precision – ≤2.0% (3.5-15.0×10^9)/L

● Linear Range – (0-100.0×10^9)/L

● Contamination Rate – ≤0.5%

● Precision – ≤1.5% (3.0-6.0×10^12)/L

● Linear Range – (0.10-8.00×10^12)/L

● Contamination Rate – ≤0.5%

● Precision – ≤1.5% (100-180) g/L

● Linear Range – (0-250) g/L

● Contamination Rate – ≤0.6%

● Precision – ≤1.0% (70-120)fL

● Linear Range – ( – )

● Contamination Rate – ( – )

● Precision – ≤4.0% (150-500×10^9)/L

● Linear Range – (0-1000×10^9)/L

● Contamination Rate – ≤1.0%

  • Power – Voltage: AC 100V~240V, 50/60Hz; Rated Power: 120VA
  • Principle – Electric impedance method and Colorimetry method
  • Parameters – WBC, LYM#, MID#, GRAN#, LYM%, MID%, GRAN%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC 3 histograms
  • Reagents – Build-in LH Lyse, External Diluent, Probe Cleaner for maintenance
  • Flag System – RBC, WBC, PLT abnormal sample and support customized test groups
  • Storage – Up to 50,000 results including histograms, scattergrams and patient information.
  • Quality Control – 3 Level QC, L-J graph, X-B

  • Calibration – Manual and Auto-calibration
  • Accessories – Standard: keyboard, waste liquid barrel, ground wire(3m); Option: mouse, external barcode scanner
  • Operational Environment – Working Temperature: 10℃~35℃; Relative Humidity: 20%~85%

Part Auto Hematology Analyzer

Compact & Fully-Automated Bench Top Analyzer
  1. Efficient testing with precision reference laboratory quality results

  2. Compatibility with two modes of sampling and various printing options

  3. User-friendly with auto-cleaning of sample probe and tubes and automatic fault processing function

  4. Low consumption of only three reagents and ≤20uL of sample

  5. Lightweight design for easy portability

    – 2 Reagents
    – 21 Parameters
    – 60 Samples/hour
    – Low consumption of reagent and sample

Application

Abdomen,Gynecology,Obstetrics,Cardiology, Small organs,Breast,Orthopedics,Urology, Blood vessels, Musculoskeletal, Nerve,Intervention etc.

Advanced Imaging Technologies

Spatial Composite Imaging. Frequency Composite Imaging. Color Panoramic Imaging. Trapezoidal Extension Imaging. Speckle Noise Reduction Imaging. Pulse Inversion Harmonic Imaging. Carotid IMT auto measurement. B/C/D Linkage Imaging. 3D/4D Imaging.

Ergonomics

Optimized control panel (angle adjustable).

19” high resolution medical LCD monitor.

10.4”Color touch screen.

4 activated transducer connectors.

Built-in keyboard drawer.

Front USB port design.

Gel warmer (optional).

Excellent Clinical Imaging

Optimized workflows

Special emphasis has been spent on the software to combine highest user friendliness with optimally secured results. A special feature is the integrated on-board hemolysis function for optimized HbA1c determination. Dynamic range extension makes additional dilutions superfluous and a dedicated STAT port allows for immediate STAT processing. Clot detection and liquid level sensor technology ensures confidence in results.

Patient friendly

The analyzer works with very small sample volumes, making it the perfect instrument in pediatric and geriatric settings.

Economic

The BioMajesty® JCA-BM6010/C is a system with one of the smallest footprint in its class hence saving precious laboratory space. DiaSys supplies ready-to-use reagents well known for their excellent on-board stability with the instrument. The result in conjunction with extremely low reagent consumption is cost efficiency on the highest order.

  • System type – Floor stand random access clinical chemistry analyzer
  • Total throughput – 1200 tests/hour
  • Sample tray STT – 84 positions for routine and priority samples with built-in barcode reader
  • Refrigerated sample tray CTT – 61 positions for controls and calibrators
  • Sample types – Serum, plasma, CSF, urine, whole blood
  • Reagent trays – Two refrigerated trays with 45 positions each for reagent containers with built-in barcode reader
  • Sample dispensing volume – 1-25 µL (0.1 µL step)
  • Reagent pipetting – 5 to 300 µL

  • STAT-analytics – STAT port enables easy STAT sample determination
  • Photometry throughput – 800 tests/hour
  • ISE throughput (Na, K, CI) – 600 tests/hour
  • Sample throughput rate – Maximum 800 samples/hour
  • Measuring principle – Colorimetry (Rate/End Point); Turbidimetric Immunoassay; ISE: simultaneous measurement of Na, K, CI
  • Barcode identification – Automatic barcode scan for reagents, samples and STAT samples
  • Calibration – Linear, non-linear, multi point
  • Sample tubes/cups – Most commonly used blood collection tubes and sample cups
  • Sample dilution – Dilution ratio: 2 to 300 times
  • Sensors – Liquid-level sensor, clot sensor and crash sensor
  • Reagent dispensing method – 2 probe system capable to dispense 3 reagent components
  • Reagent tray standard setting – Total 45 containers per tray with 40 mL
  • Reagent container capacity – 20, 40 and 70 mL with special adapters for 20 mL containers
  • Reaction disk – Rotating reaction carousel with turntable and 231 reusable plastic cuvettes
  • Reaction times and temperature – 3, 4, 5, 10, 15 minutes at 37 ± 0.1 °C; Extended reaction time: 21 or 31 minutes
  • Reflex testing capability – Yes
  • Photometry – 14 wavelengths: 340, 410, 451, 478, 505, 545, 571, 596, 658, 694, 751, 805, 845, 884 nm
  • Automatic maintenance – Automatic startup and shutdown by weekly timer
  • Required pure water – 20 Liter/hour; water purity: ≤ 1 ps/cm
  • Ambient temperature/humidity – Temperature: 18 °C to 30 °C/humidity: 40 % to 70 %
  • Power supply – AC 220 V +10 %, 50/60 Hz; 2.6 kVA
  • Dimensions – 122 cm (W) x 85 cm (D) x 110.8 cm (H)
  • Weight – Approximately 450 kg

DiaSys TLA solution

The DiaSys total Laboratory automation system (TLA) is an open, flexible and tailor-made solution for pre-analytical, analytical and post-analytical work. The pre-analytical part may consist of a tube loading module, centrifuge(s) and de-capper. Based on a high number of instrument interfaces and robotic modules users in laboratories can configure the tracking line accordingly to individual needs and expectations. Besides the DiaSys BioMajesty® JCA-BM6010/C a large selection of immunoassay- coagulation- and hematology-analyzers can be connected via bypasses for analytics. For post-analytical purposes a re-capper, a cold storage (up to 13.000 tubes) or tube unloading module (incl. retrieval option for re-testing) are available. The test ordering, sample routing and result management is controlled by a so called instrument manager software which is connected to the laboratory information system (LIS) This concept leads to optimization of processes in the daily routine of IVD laboratories, consolidation of workplaces, reduction of manual work and errors as well as improved turn around time.

Product Feature

Compatibility

Two modes of sampling: Whole blood, pre-diluted blood. Build-in thermal printer, external laser printer or inkjet printer. 

User-friendly

10.4 colorful touchscreen. Liquid Crystal Display. Resolution : 800600. 10°incline adapt to visual observation

Less Maintenance

Auto-cleaning of sample probe and tubes. Automatic fault processing function

Low Consumption

Only need three reagents. Sample consumed ≤20uL

Efficient

60 samples per hour

 

Lightweight

390mm(L)×285mm(W)×390mm(H) Weight≤16Kg

Product Video

Specifications

● Precision – ≤2.0% (3.5-15.0×10^9)/L

● Linear Range – (0-100.0×10^9)/L

● Contamination Rate – ≤0.5%

● Precision – ≤1.5% (3.0-6.0×10^12)/L

● Linear Range – (0.10-8.00×10^12)/L

● Contamination Rate – ≤0.5%

● Precision – ≤1.5% (100-180) g/L

● Linear Range – (0-250) g/L

● Contamination Rate – ≤0.6%

● Precision – ≤1.0% (70-120)fL

● Linear Range – ( – )

● Contamination Rate – ( – )

● Precision – ≤4.0% (150-500×10^9)/L

● Linear Range – (0-1000×10^9)/L

● Contamination Rate – ≤1.0%

  • Power – Voltage: AC 100V~240V, 50/60Hz; Rated Power: 120VA
  • Principle – Electric impedance method and Colorimetry method
  • Parameters – WBC, LYM#, MID#, GRAN#, LYM%, MID%, GRAN%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC 3 histograms
  • Reagents – Build-in LH Lyse, External Diluent, Probe Cleaner for maintenance
  • Flag System – RBC, WBC, PLT abnormal sample and support customized test groups
  • Storage – Up to 50,000 results including histograms, scattergrams and patient information.
  • Quality Control – 3 Level QC, L-J graph, X-B

  • Calibration – Manual and Auto-calibration
  • Accessories – Standard: keyboard, waste liquid barrel, ground wire(3m); Option: mouse, external barcode scanner
  • Operational Environment – Working Temperature: 10℃~35℃; Relative Humidity: 20%~85%

Part Auto Hematology Analyzer

Compact & Fully-Automated Bench Top Analyzer
  1. Efficient testing with precision reference laboratory quality results

  2. Compatibility with two modes of sampling and various printing options

  3. User-friendly with auto-cleaning of sample probe and tubes and automatic fault processing function

  4. Low consumption of only three reagents and ≤20uL of sample

  5. Lightweight design for easy portability

    – 2 Reagents
    – 21 Parameters
    – 60 Samples/hour
    – Low consumption of reagent and sample

Application

Abdomen,Gynecology,Obstetrics,Cardiology, Small organs,Breast,Orthopedics,Urology, Blood vessels, Musculoskeletal,Nerve,Intervention etc.

Advanced Imaging Technologies

Spatial Composite Imaging. Frequency Composite Imaging. Color Panoramic Imaging. Trapezoidal Extension Imaging. Speckle Noise Reduction Imaging. Pulse Inversion Harmonic Imaging. Carotid IMT auto measurement. B/C/D triplex Imaging. 3D/4D Imaging.

Ergonomics

Optimized control panel (angle adjustable)
19” high resolution medical LCD monitor
10.4”Color touch screen
4 activated transducer connectors
Built-in keyboard drawer
Front USB port design
Built-in lithium battery (optional)
Gel warmer (optional)

Excellent Clinical Imaging

Optimized workflows

Special emphasis has been spent on the software to combine highest user friendliness with optimally secured results. A special feature is the integrated on-board hemolysis function for optimized HbA1c determination. Dynamic range extension makes additional dilutions superfluous and a dedicated STAT port allows for immediate STAT processing. Clot detection and liquid level sensor technology ensures confidence in results.

Patient friendly

The analyzer works with very small sample volumes, making it the perfect instrument in pediatric and geriatric settings.

Economic

The BioMajesty® JCA-BM6010/C is a system with one of the smallest footprint in its class hence saving precious laboratory space. DiaSys supplies ready-to-use reagents well known for their excellent on-board stability with the instrument. The result in conjunction with extremely low reagent consumption is cost efficiency on the highest order.

  • System type – Floor stand random access clinical chemistry analyzer
  • Total throughput – 1200 tests/hour
  • Sample tray STT – 84 positions for routine and priority samples with built-in barcode reader
  • Refrigerated sample tray CTT – 61 positions for controls and calibrators
  • Sample types – Serum, plasma, CSF, urine, whole blood
  • Reagent trays – Two refrigerated trays with 45 positions each for reagent containers with built-in barcode reader
  • Sample dispensing volume – 1-25 µL (0.1 µL step)
  • Reagent pipetting – 5 to 300 µL

  • STAT-analytics – STAT port enables easy STAT sample determination
  • Photometry throughput – 800 tests/hour
  • ISE throughput (Na, K, CI) – 600 tests/hour
  • Sample throughput rate – Maximum 800 samples/hour
  • Measuring principle – Colorimetry (Rate/End Point); Turbidimetric Immunoassay; ISE: simultaneous measurement of Na, K, CI
  • Barcode identification – Automatic barcode scan for reagents, samples and STAT samples
  • Calibration – Linear, non-linear, multi point
  • Sample tubes/cups – Most commonly used blood collection tubes and sample cups
  • Sample dilution – Dilution ratio: 2 to 300 times
  • Sensors – Liquid-level sensor, clot sensor and crash sensor
  • Reagent dispensing method – 2 probe system capable to dispense 3 reagent components
  • Reagent tray standard setting – Total 45 containers per tray with 40 mL
  • Reagent container capacity – 20, 40 and 70 mL with special adapters for 20 mL containers
  • Reaction disk – Rotating reaction carousel with turntable and 231 reusable plastic cuvettes
  • Reaction times and temperature – 3, 4, 5, 10, 15 minutes at 37 ± 0.1 °C; Extended reaction time: 21 or 31 minutes
  • Reflex testing capability – Yes
  • Photometry – 14 wavelengths: 340, 410, 451, 478, 505, 545, 571, 596, 658, 694, 751, 805, 845, 884 nm
  • Automatic maintenance – Automatic startup and shutdown by weekly timer
  • Required pure water – 20 Liter/hour; water purity: ≤ 1 ps/cm
  • Ambient temperature/humidity – Temperature: 18 °C to 30 °C/humidity: 40 % to 70 %
  • Power supply – AC 220 V +10 %, 50/60 Hz; 2.6 kVA
  • Dimensions – 122 cm (W) x 85 cm (D) x 110.8 cm (H)
  • Weight – Approximately 450 kg

DiaSys TLA solution

The DiaSys total Laboratory automation system (TLA) is an open, flexible and tailor-made solution for pre-analytical, analytical and post-analytical work. The pre-analytical part may consist of a tube loading module, centrifuge(s) and de-capper. Based on a high number of instrument interfaces and robotic modules users in laboratories can configure the tracking line accordingly to individual needs and expectations. Besides the DiaSys BioMajesty® JCA-BM6010/C a large selection of immunoassay- coagulation- and hematology-analyzers can be connected via bypasses for analytics. For post-analytical purposes a re-capper, a cold storage (up to 13.000 tubes) or tube unloading module (incl. retrieval option for re-testing) are available. The test ordering, sample routing and result management is controlled by a so called instrument manager software which is connected to the laboratory information system (LIS) This concept leads to optimization of processes in the daily routine of IVD laboratories, consolidation of workplaces, reduction of manual work and errors as well as improved turn around time.

Product Feature

Compatibility

Two modes of sampling: Whole blood, pre-diluted blood. Build-in thermal printer, external laser printer or inkjet printer. 

User-friendly

10.4 colorful touchscreen. Liquid Crystal Display. Resolution : 800600. 10°incline adapt to visual observation

Less Maintenance

Auto-cleaning of sample probe and tubes. Automatic fault processing function

Low Consumption

Only need three reagents. Sample consumed ≤20uL

Efficient

60 samples per hour

 

Lightweight

390mm(L)×285mm(W)×390mm(H) Weight≤16Kg

Product Video

Specifications

● Precision – ≤2.0% (3.5-15.0×10^9)/L

● Linear Range – (0-100.0×10^9)/L

● Contamination Rate – ≤0.5%

● Precision – ≤1.5% (3.0-6.0×10^12)/L

● Linear Range – (0.10-8.00×10^12)/L

● Contamination Rate – ≤0.5%

● Precision – ≤1.5% (100-180) g/L

● Linear Range – (0-250) g/L

● Contamination Rate – ≤0.6%

● Precision – ≤1.0% (70-120)fL

● Linear Range – ( – )

● Contamination Rate – ( – )

● Precision – ≤4.0% (150-500×10^9)/L

● Linear Range – (0-1000×10^9)/L

● Contamination Rate – ≤1.0%

  • Power – Voltage: AC 100V~240V, 50/60Hz; Rated Power: 120VA
  • Principle – Electric impedance method and Colorimetry method
  • Parameters – WBC, LYM#, MID#, GRAN#, LYM%, MID%, GRAN%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC 3 histograms
  • Reagents – Build-in LH Lyse, External Diluent, Probe Cleaner for maintenance
  • Flag System – RBC, WBC, PLT abnormal sample and support customized test groups
  • Storage – Up to 50,000 results including histograms, scattergrams and patient information.
  • Quality Control – 3 Level QC, L-J graph, X-B

  • Calibration – Manual and Auto-calibration
  • Accessories – Standard: keyboard, waste liquid barrel, ground wire(3m); Option: mouse, external barcode scanner
  • Operational Environment – Working Temperature: 10℃~35℃; Relative Humidity: 20%~85%